Saturn Pyro Sdn Bhd
Johor Bahru Office

44 & 44A, Jalan Palma Rafis 1,
Taman Dato Chellam,
81800 Ulu Tiram,
Johor, Malaysia.
+607-8660510
+607-8660511
enquiry@saturnpyro.com

Shah Alam Office
K03-03-12, Tower 3,
UOA Business Park,
No 1, Jalan
Pengaturcara U1/51A,
Section U1, Kawasan
Perindustrian Temasya,
40150 Shah Alam,
Selangor, Malaysia.
+607-8660510
+607-8660511
desmond@saturnpyro.com

Penang Office
Penthouse 1-21-1,
Suntech @ Penang Cybercity
Lintang Mayang Pasir 3,
11950 Bayan Baru,
Penang, Malaysia.
+607-8660510
+607-8660511
desmond@saturnpyro.com

Singapore Office
Saturn Pyro Pte Ltd
101 Kitchener Road,
#02-42 Jalan Besar Plaza,
Singapore 208511.
+607-8660510
+607-8660511
jerry@saturnpyro.com
 
India Office
3, Gr Floor, Eishita,
Shiv Vallabh Cross Road,
Ashokvan, Dahisar (E.),
Mumbai 400068.
+91 22284 84682
+91 98191 56654

CIR-e3

Previous 6 / 8 Next

CIR-e3 Portable Power Analyzers


Download Files

CIRe3_pdf.pdf (810.1 KB)
Product Description

The CIR-e family are the lower-range CIRCUTOR analyzers, but offer as many benefits. They make up a family of counters which allow the technician to obtain the electrical parameters necessary to perform energy audits and power quality. They don't have a display screen. The measured parameters are recorded in 2 quadrants. They are accompanied by an executable configuration program and the records are stored on an SD card.

The records generated by these portable analyzers can be analyzed using the web tool found at http://cir-e3.circutor. com and/or with the Power Vision or Power Vision Plus software.

Features:
  • Measure in 2 quadrants the main parameters for single-phase and three-phase electrical networks with 3 and 4 wires.
  • True root mean square measure
  • Built-in energy meter.
  • 4 voltage channels and 3 current channels.
  • Configurable via PC application.
  • Recording of parameters on SD card (up to 2 Gb).
  • Compatible with Power Vision software.
  • Possibility of custom-made independent power supply allowing power supply ranges of 100 to 400 Vac and 70 to 315 Vdc.
  • Reduced size which allows installation in boxes with standard double insulation.
  • Light
  • Automatic detection of pins.
  • Indication of poor connection of voltages and current pins.
  • Compatible with CIR-e WEB application for processing data via a web site.
  • Magnetic attachment to facilitate fastening to an electric panel or metal supports.
Application:
  • Equipment for performing energy audits
CIRe3 Dimension

Specification:

Power circuit
Voltage 100 to 400 Vac, 70 to 315 Vdc
Frequency 50...60 Hz
Consumption 9 VA
Measurement circuit
Voltage ( f-N ) 10 to 400 Vac (f-N) ± 10%
Voltage f-f 17 to 690 Vac (f-f) ± 10%
Current (.../2 V) 2.5 to 100% F.E. of clamp (within class)
Frequency 45 to 65 Hz
Minimum/maximum current, in accordance with the clamp and scale
Clamp Scale Range
E-FLEX 20/54 cm L1/sc1 200 A 5 to 200 A
L2/sc2 2 000 A 50 to 2000 A
L3/sc3 20 000 A 500 to 20,000 A
CP-5 5 A 0.05 to 5 A
CP-100 100 A 1 to 100 A
Accuracy
Voltage 0,5 % F.E.
Current 1 % F.E.
Power 2 % F.E.
Energy 2 % F.E.
Build features
Operating temperature 10 to 50ºC
Altitude 2 000 m
Humidity 95% RH without condensation
Storage temperature -10 to 65ºC
Protection degree IP 53
Weight (only CIRe3) 0.677 kg
Weight (with packaging) 0.733 kg
Standards
ELECTRICAL SAFETY STANDARD: IEC 60664-1, IEC 61010-1, IEC 62053-21, UL 94, VDE 110 ELECTROMAGNETIC EMISSIONS: IEC 61000-3-2, IEC 61000-3-3, IEC 61000-6-4, EN 55011, EN 55022 ELECTROMAGNETIC IMMUNITY: IEC 61000-6-2, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-8, IEC 61000-6-1, IEC 61000-4-11, ENV 50141

Saturn Pyro is an authorized distributor/reseller in Malaysia. Circutor CIR-e3 Portable Power Analyzer / Data Logger / Energy Logger Malaysia. Available in Penang, KL, Selangor, Johor & anywhere in Malaysia & Singapore.

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version